Flow Boiling Demonstration TH-3120
Technical Information
| Parameter | Description |
|---|---|
| Heater Power Rating | 2kW |
| Heater Temperature Range | -100~400°C |
| Pump Max. Flow Rate | 1.9m³/h |
| Pump Max. Head | 1.5m |
| Pump Power Consumption | 58W |
| Liquid for Evaporation Quantity | 0.5L |
| Liquid Pressure Range | -1.0~1.5bar relative |
| Condenser | copper coil |
| Water Jet Pump Required Water Pressure | 0.5bar |
| Water Jet Pump Flow Rate | 4~12L/min |
| Water Jet Pump Final Pressure | 16mbar |
| Tube Evaporator Length | 1200mm |
| Tube Evaporator Inner Diameter | 13.6mm |
| Tube Evaporator Outer Diameter | 24mm |
| Measuring Range (Pressure) | -1~1.5bar relative |
| Measuring Range (Temperature) | -100~400°C |
Experiments Included
- Observation of typical forms of evaporation
- Single phase liquid flow
- Bubbly flow
- Slug flow
- Annular flow
- Film boiling
- Drop flow (mist)
- Single phase vapour flow
- Effect on the evaporation process by:
- Flow rate
- Temperature
- Pressure
Flow Boiling Demonstration (TH-3120)
The Flow Boiling Demonstration (TH-3120) is designed to demonstrate the process of evaporation in heated pipes as occurs in water-tube boilers. The different phases that appear during evaporation in the pipe can be clearly observed. The double-wall glass evaporation pipe allows close observation of the evaporation process. Hot water flows through the outer pipe and evaporates the medium in the inner pipe. The non-toxic liquid used starts to evaporate at 40 to 50°C. Low system pressures can be generated using the built-in water jet pump.
The pipe systems are clearly laid out on a metal panel. The hot water circuit consists of an expansion vessel, a circulating pump, and a heater. An evaporation pipe, vapour collector, water-cooled condenser, and return pipe form the evaporation circuit.
Features
- Demonstrates evaporation in heated pipes
- Clear observation of different phases during evaporation
- Double-wall glass evaporation pipe for close process observation
- Hot water flows through the outer pipe and evaporates the medium in the inner pipe
- Non-toxic liquid starts to evaporate at 40 to 50°C
- Low system pressures generated using the built-in water jet pump
- Pipe systems mounted and clearly laid out on a metal panel
- Hot water circuit includes expansion vessel, circulating pump, and heater
- Evaporation circuit includes evaporation pipe, vapour collector, water-cooled condenser, and return pipe
Educational Objectives / Learning Outcomes
- Observation of typical forms of evaporation
- Investigation of the effect of flow rate on the evaporation process
- Investigation of the effect of temperature on the evaporation process
- Investigation of the effect of pressure on the evaporation process
- Observation of:
- Single phase liquid flow
- Bubbly flow
- Slug flow
- Annular flow
- Film boiling
- Drop flow (mist)
- Single phase vapour flow
Standard Accessories
- Laboratory trolley with strong HDF sheet
- Evaporation pipe made of double-wall glass, heated with hot water
- Evaporation in inner pipe, heating in the outer sheath
- Circulating pump
- Water jet pump for generating partial vacuum
- CFC free evaporation liquid
Optional Accessories (If Available)
Software TH-3120SW (optional)
- DAQ software specially designed in National Instrument™, LABVIEW™ environment to measure and calculate the results of apparatus.
- While using software a set of electronic sensors are included.